chevron-left chevron-right chevron-up chevron-right chevron-left arrow-back star phone quote checkbox-checked search wrench info shield play connection mobile coin-dollar spoon-knife ticket pushpin location gift fire feed bubbles home heart calendar price-tag credit-card clock envelop facebook instagram twitter youtube pinterest yelp google reddit linkedin envelope bbb pinterest homeadvisor angies

Federal Pacific Breaker Panel

 

As a homeowner in the 02910 zip code of Cranston, Providence, Rhode Island, one of the most important things you need to have is a safe and reliable electrical system. Without a properly functioning electrical system, your home and daily activities can be greatly affected. From lights to appliances to security systems, your electrical system powers everything in your home. And at the heart of your electrical system lies your breaker panel.

Your breaker panel, also known as a circuit breaker box, is responsible for distributing electricity throughout your home and protecting your electrical system from overloads and short circuits. It is an essential component of any home’s electrical system, and it is important to ensure that it is in good working condition at all times.

We often take our electrical systems for granted. We flick a switch and expect the lights to turn on, or plug in an appliance and expect it to work without any issues. But what we often fail to realize is that behind these simple actions lies a complex network of wiring and circuits that require proper maintenance and care. And when it comes to breaker panels, one brand that has garnered a lot of attention in recent years is the Federal Pacific breaker panel.

At B&K Electric, a family-owned and operated electrical business based in Warwick, RI, we have been providing top-notch electrical services to the residents of Cranston, Warwick, and all of Rhode Island for over seventeen years. With our expertise in electrical repair, panel maintenance, and installation, we have extensive knowledge about various breaker panel brands, including the infamous Federal Pacific.

What Is a Federal Pacific Breaker Panel?

The Federal Pacific breaker panel, also known as FPE, was once one of the most commonly used brands in North America from the 1950s to the 1980s. It was especially popular in the Northeastern United States, including Rhode Island, where it was installed in numerous homes and businesses.

At first glance, the Federal Pacific breaker panel may seem like any other circuit breaker box. However, what sets it apart is its unique design that was patented in the 1940s. Unlike traditional breaker panels that use a double pole system, Federal Pacific’s design features a single pole design, which means that instead of two separate circuits, there is only one. This design was marketed as being more compact and cost-effective, making it popular among builders and homeowners.

Issues with Federal Pacific Breaker Panels

While the single pole design may have seemed like a revolutionary move in the 1940s, it eventually proved to have significant flaws. One of the major concerns with Federal Pacific breaker panels is their inability to trip when overloaded or short-circuited. This means that instead of cutting off the power supply, the breaker may stay in the “on” position, posing a serious fire hazard.

In fact, studies have shown that Federal Pacific breaker panels have an alarming failure rate of up to 25%, which is significantly higher than other brands. This has led to countless reports of fires caused by these breaker panels, resulting in property damage and, in some cases, even fatalities.

Furthermore, Federal Pacific breakers have also been found to have issues with double tapping. This is when more than one wire is connected to a breaker, which can lead to overheating and potential fires.

Should You Replace Your Federal Pacific Breaker Panel?

As a licensed electrician servicing the residence of the 02910 zip code and beyond, we highly recommend homeowners with Federal Pacific breaker panels to consider replacing them. While not all Federal Pacific breaker panels may pose a risk, the statistics are concerning enough to warrant a closer look at your home’s electrical system.

One way to determine if you have a Federal Pacific breaker panel is by looking at the label on the inside of the panel door. If the brand name is Federal Pacific Electric, Stab-Lok, or Federal Pacific, then it is a Federal Pacific breaker panel. You can also check for a red strip or sticker, indicating that the breaker has been inspected or deemed unsafe.

Another way to verify the safety of your breaker panel is by having a licensed electrician perform an inspection. They can check for any signs of damage or overheating and determine if your breaker panel needs to be replaced. Keep in mind that even if your panel is not showing any visible issues, it is better to be safe than sorry when it comes to your home and family’s safety.

Trust B&K Electric for Your Breaker Panel Needs

At B&K Electric, we understand the importance of having a safe and reliable electrical system. That’s why our team of professional and experienced electricians is dedicated to providing top-quality service for all your electrical needs. From repairs to maintenance to panel installations, we have you covered. We use only the best and most reliable brands, ensuring the safety and efficiency of your electrical system.

If you’re a homeowner in the 02910 zip code of Cranston, Providence, Rhode Island, make B&K Electric your go-to for all your electrical needs. We pride ourselves on our exceptional customer service and commitment to our community, making us the trusted choice for many in the greater Warwick and Providence areas.